Accessible Means of Egress
An exit path specifically designed so a person who cannot use stairs can evacuate independently or wait safely for assistance, typically through an accessible route to an exit, an area of refuge, or an elevator designated for emergency use by trained responders.
Why it matters
Standard means of egress requirements, covering general exit width and travel distance, don't by themselves guarantee a wheelchair user can actually get out of a multi-story building during a fire, which is exactly the gap accessible means of egress requirements exist to close.
On a real project
A multi-story building's design includes a fire-rated area of refuge adjacent to an exit stairwell, where a wheelchair user can wait safely with a two-way communication system to alert responders, since the stairwell itself isn't usable without that assistance.
Who this matters most to
The Architect and the Code Consultant need to verify accessible egress separately from general egress requirements, since a building can satisfy standard exit-width and travel-distance rules while still failing to provide any way for a mobility-impaired occupant to actually evacuate.
Where this goes wrong
People sometimes assume that meeting standard egress requirements for exit width and number of exits automatically covers accessibility too, when a mobility-impaired occupant needs a specifically designed accessible route, refuge area, or evacuation elevator that standard egress calculations don't address.