Skip to main content
Concept

Mass Timber & Cross-Laminated Timber (CLT)

Large, engineered wood structural panels and members, most commonly CLT, made by gluing layers of lumber together in alternating directions, strong and dimensionally stable enough to replace steel or concrete in a building's primary structure, now permitted up to 18 stories under the 2021 IBC's new Type IV-A construction classification.

Why it matters

Mass timber sequesters carbon in the building's own structure rather than emitting it the way steel and concrete production do, but it also changes the fire-protection strategy entirely: Type IV-A buildings require a specific combination of exposed-timber limits and noncombustible protection the code didn't need to address before mass timber could go this tall.

On a real project

A 12-story apartment building is designed under the 2021 IBC's Type IV-B classification, which caps exposed mass timber surface area and requires the rest of the structural CLT to be protected with gypsum wallboard, a fire-rating tradeoff a conventional steel building never has to make.

Who this matters most to

A Structural Engineer designing a mass timber building has to coordinate the structural design with the specific IV-A, IV-B, or IV-C classification the project is pursuing, since each caps height and exposed-timber area differently.

Where this goes wrong

A design team specifies mass timber assuming it automatically qualifies for the tallest 18-story IBC allowance, when the taller classifications (Type IV-A) require nearly all structural timber to be fully protected, and only the shorter IV-C classification allows broad timber exposure.