Radon Mitigation System
CSI Division 02, Existing Conditions
A system, most often active sub-slab depressurization (a continuously running fan drawing soil gas from beneath the foundation through a sealed pipe and venting it above the roofline), installed to reduce indoor radon gas below the EPA's 4 pCi/L action level.
Why it matters
Radon is an invisible, odorless radioactive gas that seeps up from soil and is a leading cause of lung cancer in non-smokers; a home or building can only be shown to need mitigation through testing, since there's no way to detect it without equipment.
On a real project
After a pre-sale radon test comes back at 6 pCi/L, a contractor installs a sub-slab depressurization system, sealing foundation cracks and running a vent pipe with an inline fan from beneath the slab to above the roof, then retests to confirm the level has dropped below 2 pCi/L.
Who this matters most to
A HVAC Technician or specialized radon contractor installs and tests the system, often working alongside the Environmental Remediation Specialist handling the broader indoor-air assessment.
Where this goes wrong
A mitigation system is installed but the fan is undersized for the house's foundation layout, and a post-installation retest still shows radon above the action level, meaning the homeowner paid for a system that doesn't actually solve the problem.